{"id":5675,"date":"2026-10-30T10:07:14","date_gmt":"2026-10-30T09:07:14","guid":{"rendered":"https:\/\/lafagianata.it\/en\/cycling-power-zones-explained-z1-to-z7-what-they-are-and-how-cyclists-use-them\/"},"modified":"2026-11-12T00:54:22","modified_gmt":"2026-11-11T23:54:22","slug":"cycling-power-zones-explained-z1-to-z7-what-they-are-and-how-cyclists-use-them","status":"publish","type":"post","link":"https:\/\/lafagianata.it\/en\/cycling-power-zones-explained-z1-to-z7-what-they-are-and-how-cyclists-use-them\/","title":{"rendered":"Cycling Power Zones Explained: Z1 to Z7, What They Are and How Cyclists Use Them"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Power zones are seven levels of effort, from active recovery to neuromuscular power, calculated as a percentage of threshold: FTP, the power a cyclist can hold in a quasi-steady state for about an hour. Z1 is the easiest pedalling, Z7 the sprint lasting a few seconds; in between come endurance, tempo, threshold, VO2max and anaerobic capacity. A wattage on its own does not tell you which zone you are in: it does so only when set against the FTP of the rider pedalling.<\/p>\n\n\n\n<div class=\"wp-block-group in-sintesi has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"etichetta wp-block-paragraph\">Key points<\/p>\n\n\n<ul class=\"wp-block-list\"><li>Seven power levels, all measured as a percentage of threshold (FTP) and not of VO2max.<\/li><li>For amateurs, FTP is estimated as 95% of the average power of a 20-minute test.<\/li><li>Between test FTP and respiratory threshold the correlation is high (r = 0.916), but the gap for an individual exceeds \u00b140 W.<\/li><li>On the pros&#8217; climbs the zone depends on the duration of the effort: six minutes are not twenty-six.<\/li><\/ul>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Take Selvino, the climb of Il Lombardia 2026: 10.1 km, 596 metres of elevation gain, <a href=\"\/en\/what-a-10-climb-really-means-gradient-elevation-gain-and-effort-at-il-lombardia-2026\/\">average gradient<\/a> of 5.9%. The head of the race climbed it in 26\u203246\u2033, at about 4.5-6.0 W\/kg. An amateur of 75 kg pushing 280 W takes 34\u203217\u2033. It is the same road, but each person measures it against their own threshold and for a different duration, and the same climb can fall in different zones.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The seven zones are derived from FTP and each has a duration that can be held; on the measured climbs of the <a href=\"\/en\/climb-timer\/\">Climb timer<\/a> the zone depends on the duration of the effort.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The seven power zones from Z1 to Z7<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">There are seven zones because seven is the minimum needed to cover all the physiological responses that competitive cycling demands. Those who drew them up know well that intensity is a continuum and that every boundary is partly arbitrary: the lines are there to help you get your bearings, not to separate two different bodies.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Level<\/th><th>Name<\/th><th>% of FTP<\/th><th>Typical duration<\/th><\/tr><\/thead><tbody><tr><td>Z1<\/td><td>Active recovery<\/td><td>below 55<\/td><td>\u2014<\/td><\/tr><tr><td>Z2<\/td><td>Endurance<\/td><td>56-75<\/td><td>\u2014<\/td><\/tr><tr><td>Z3<\/td><td>Tempo<\/td><td>76-90<\/td><td>\u2014<\/td><\/tr><tr><td>Z4<\/td><td>Threshold<\/td><td>91-105<\/td><td>\u2014<\/td><\/tr><tr><td>Z5<\/td><td>VO2max<\/td><td>106-120<\/td><td>from 3 to about 8 minutes<\/td><\/tr><tr><td>Z6<\/td><td>Anaerobic capacity<\/td><td>121-150<\/td><td>2 minutes or less<\/td><\/tr><tr><td>Z7<\/td><td>Neuromuscular power<\/td><td>very short efforts<\/td><td>under 10 seconds<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Coggan&#8217;s seven zones: each level is a band of threshold (FTP). Durations are given only where known.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The anchor is threshold, not VO2max. The reason is that power at threshold sums up three things in a single number: VO2max, the fraction of VO2max that can be sustained and pedalling efficiency. It is the most important determinant of endurance performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zones are read on the average, or normalised power, of the ride or the repetition. A gust of headwind or a ramp that takes you briefly over the limit does not change the level of the work. Duration matters too: power and time are inversely related, so those doing short efforts sit at the top of a zone&#8217;s range and those doing long ones at the bottom.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FTP in one line<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">FTP is <mark>the average sustainable power<\/mark> in a quasi-steady state for 60 minutes. This is the definition of the person who proposed it, and it is the number from which all the zones derive.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An hour flat out is hard for an amateur to sustain. So a shortened protocol is used, the 20-minute test, from which FTP is estimated. How it is done, and what differs between the ramp test and the one-hour test, is explained in the guide to <a href=\"\/en\/what-is-ftp-and-how-is-it-measured-the-20-minute-ramp-and-one-hour-tests-explained\/\">what FTP is and how it is measured<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Once you have your FTP, the zones become watts. The worked example is a cyclist with an FTP of 290 W.<\/p>\n\n\n\n<div class=\"wp-block-group conto has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"etichetta wp-block-paragraph\">The calculation<\/p>\n\n\n<ol class=\"wp-block-list\"><li>Z1: 55% of 290 is 159.5, so up to about 160 W.<\/li><li>Z3 (tempo): 219 to 261 W.<\/li><li>Z5 (VO2max): 306 to 348 W.<\/li><\/ol>\n\n\n<p class=\"conto__risultato wp-block-paragraph\">The same percentage gives different watts to different people: 76% of one cyclist&#8217;s FTP is not 76% of another&#8217;s.<\/p>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">How much you can hold in each zone<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Z1 to Z3: base and tempo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Z1 is active recovery, Z2 endurance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Z3, tempo, is the level at which the cyclist spends the most time and is <mark>where the average power falls<\/mark> in road races. In a race, though, the same average weighs more than in training, because in a race power varies far more and hits higher peaks.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Z4: threshold and the sweet spot<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Z4 sits around FTP. Inside this zone is the sweet spot, straddling tempo and threshold: the sweet spot lies between 88% and 95% of FTP, depending on how it is defined. The boundaries, in short, are not rigid.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the laboratory, power at the respiratory compensation point (RCP) and the maximal lactate steady state mark the boundary between heavy and severe: the upper limit of effort sustainable without a progressive build-up of metabolic fatigue. FTP lies in the heavy domain, and working at or just above FTP is not enough to reach VO2max.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Z5, Z6 and Z7: where little can be held<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Above threshold, durations matter more than percentages. Z5, VO2max, calls for intervals of at least 3 minutes to stimulate the system, up to about 8: beyond 8 minutes most cyclists can no longer hold 106-120% of FTP.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Z6, anaerobic capacity, means efforts of 2 minutes or less, at a power above 100% of VO2max. Z7 is <mark>efforts under 10 seconds<\/mark>: they load the neuromuscular system more than the metabolic one, and during the sprint looking at the meter is of little use.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Zones, weight and watts per kilo: amateurs and female riders<\/h2>\n\n\n\n<div class=\"wp-block-group conto has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"etichetta wp-block-paragraph\">The calculation<\/p>\n\n\n<ol class=\"wp-block-list\"><li>280 W \u00f7 65 kg = 4.3 W\/kg<\/li><li>280 W \u00f7 75 kg = 3.7 W\/kg<\/li><\/ol>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Weight changes the pace, not the zone<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The zones are percentages of threshold and apply to everyone, whether you weigh 55 or 95 kilos. What changes is the watts those percentages translate into, and they change with the person and with weight. That is why the comparison with the amateur in the examples starts from a simple calculation, watts divided by kilos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The same effort, two different bodies: the zone stays the same, weight decides how fast the bike goes when the road climbs. The same power produces a brisker pace for the lighter rider, which is why on climbs watts per kilo count for more than watts. For the full picture, see the guide to <a href=\"\/en\/watts-per-kilo-amateur-professional\/\">watts per kilo for amateurs and professionals<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">The same zones apply to female riders<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">And women? In a study of 49 amateur triathletes, 25 men and 24 women, the relationship between FTP and power at the respiratory compensation point does not change between the sexes. Related to lean mass, power does not differ: FTP is around 3.9 W per kilo of lean mass in both. So the same zones and the same numbers for men and women; for the real physiological differences, see the guide to <a href=\"\/en\/women-cyclists-physiology-vo2max-threshold-and-watts-per-kilo-compared-with-men\/\">female cyclists<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The pros on the climbs of Il Lombardia 2026<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Climb<\/th><th class=\"has-text-align-right\" data-align=\"right\">Time<\/th><th class=\"has-text-align-right\" data-align=\"right\">VAM (m\/h)<\/th><th class=\"has-text-align-right\" data-align=\"right\">W\/kg<\/th><\/tr><\/thead><tbody><tr><td>Selvino<\/td><td class=\"has-text-align-right\" data-align=\"right\">26\u203246\u2033*<\/td><td class=\"has-text-align-right\" data-align=\"right\">1.340<\/td><td class=\"has-text-align-right\" data-align=\"right\">4,5-6,0<\/td><\/tr><tr><td>Valpiana<\/td><td class=\"has-text-align-right\" data-align=\"right\">25\u203258\u2033*<\/td><td class=\"has-text-align-right\" data-align=\"right\">1.460<\/td><td class=\"has-text-align-right\" data-align=\"right\">5,1-6,4<\/td><\/tr><tr><td>Giovenzana<\/td><td class=\"has-text-align-right\" data-align=\"right\">13\u203200\u2033*<\/td><td class=\"has-text-align-right\" data-align=\"right\">1.540<\/td><td class=\"has-text-align-right\" data-align=\"right\">4,9-5,8<\/td><\/tr><tr><td>Madonna del Ghisallo<\/td><td class=\"has-text-align-right\" data-align=\"right\">19\u203219\u2033<\/td><td class=\"has-text-align-right\" data-align=\"right\">1.650<\/td><td class=\"has-text-align-right\" data-align=\"right\">6,0-7,6<\/td><\/tr><tr><td>San Fermo della Battaglia (1st)<\/td><td class=\"has-text-align-right\" data-align=\"right\">6\u203210\u2033<\/td><td class=\"has-text-align-right\" data-align=\"right\">1.900<\/td><td class=\"has-text-align-right\" data-align=\"right\">6,7-8,3<\/td><\/tr><tr><td>Civiglio<\/td><td class=\"has-text-align-right\" data-align=\"right\">12\u203216\u2033*<\/td><td class=\"has-text-align-right\" data-align=\"right\">1.990<\/td><td class=\"has-text-align-right\" data-align=\"right\">6,4-7,7<\/td><\/tr><tr><td>San Fermo della Battaglia (2nd)<\/td><td class=\"has-text-align-right\" data-align=\"right\">6\u203217\u2033<\/td><td class=\"has-text-align-right\" data-align=\"right\">1.860<\/td><td class=\"has-text-align-right\" data-align=\"right\">6,6-8,1<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Climbs of Il Lombardia 2026 with time, VAM and watts per kilo as a range. Madonna del Ghisallo is left out of the comparison: it is climbed fast, air resistance weighs more than 15% and the estimate is weak.<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">The measured climbs give a range, not a zone<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To see where the pros sit, we take the climbs of Il Lombardia 2026 measured by climbing time: San Fermo della Battaglia on the first and second passes, Civiglio, Giovenzana, Selvino and Valpiana. The zone remains indicative: the individual rider&#8217;s FTP is not known, and the range of watts per kilo is the effort of that day, not their threshold.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What counts is the duration of the effort<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">What counts is duration. The roughly 6 minutes of San Fermo fall within the VO2max window in the book: <mark>Z5, VO2max<\/mark> extends up to about 8 minutes. The roughly 12 minutes of Civiglio exceed it.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Selvino and Valpiana last about 26 minutes: too long for Z5. The \u201cat least\u201d threshold is about 4.4-5.7 W\/kg on Selvino and about 4.8-6.2 W\/kg on Valpiana: on these two climbs it is the figure to watch, not the zone.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Try the climb against your own time<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">How these numbers are reached and what weighs on the estimates is in <a href=\"\/en\/method\/\">How we work<\/a>; you try the climb against your own time in the <a href=\"\/en\/climb-timer\/\">Climb timer<\/a>, and for climbing speed there is the guide to <a href=\"\/en\/vam-in-cycling-explained-what-average-ascent-speed-is-and-how-to-calculate-it\/\">VAM<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">In a race the zones blend: the 2020 Vuelta a Espa\u00f1a<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">The Vuelta zones are built on critical power<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A race is not a session with the zones lined up in a row. The study of the 2020 Vuelta a Espa\u00f1a followed 36 male professionals and uses zones built on <a href=\"\/en\/critical-power-and-w%e2%80%b2-explained-the-model-behind-cycling-attacks\/\">critical power<\/a>, not FTP: they are a different scale, not to be laid over Coggan&#8217;s. Low intensity is below 70% of critical power, medium between 70% and 100%, high above. Critical power comes from the best efforts of 3, 6 and 12 minutes over the three weeks.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The climbers, 13 riders of about 63.9 \u00b1 3.3 kg, spend about 66% of the time at low intensity on mountain stages. Yet at the start of the stage they set off with about 911 seconds above critical power. On semi-mountainous stages low intensity rises to about 70.5%, on flat stages to about 91%.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">The hard efforts are on the first climbs<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><mark>The hard efforts<\/mark> are on the first climbs: climbers lose about 40.70 seconds of high intensity for every 10% of the stage, while average power rises by 8.45 W. The average load is 329 in the mountains, 280 on semi-mountainous stages and 217 on the flat.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The climbers&#8217; normalised power starts from about 285 W, with an intensity factor of about 0.76. The race numbers, with the date of each, are in the Analyses.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Where the number is not enough<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The zones are a useful convention, and their boundaries are partly arbitrary: seven levels are the minimum number needed to cover the physiological responses of competitive cycling, not a law.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">FTP and physiological threshold do not coincide<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In the 20-minute test of the 49 amateur triathletes, FTP comes out lower than physiological threshold, the power at the respiratory compensation point: by 29.21 W in men (233.59 against 262.80 W) and by 14.43 W in women (168.90 against 183.33 W).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The limits of agreement exceed \u00b140 W, wider than the typical distance between one zone and the next: for an individual the boundary can fall in the wrong zone.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Studies on the relationship between FTP and lactate threshold diverge. In recreational cyclists FTP comes out lower, in well-trained ones the two values are similar: it depends on level and protocol. To measure it, see the guide to<a href=\"\/en\/what-is-ftp-and-how-is-it-measured-the-20-minute-ramp-and-one-hour-tests-explained\/\">FTP and its tests<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Above threshold, fixed percentages get it wrong<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">iLevels come from riders who don&#8217;t fit the model: with similar FTPs, some held 5 minutes at 150% of threshold and others struggled at 105%. There are nine levels, with eight boundaries drawn from the power-duration curve, and they differ from the classic ones <mark>only above threshold<\/mark>: below, levels 1 to 4 suit almost everyone.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The book&#8217;s example has an FTP of 290 W. Classic level 6 would be 351-435 W, but that rider&#8217;s curve says 697 W at 28 seconds and 471 W at 1&#8217;33&#8221;: fixed percentages above threshold can be badly wrong.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Laboratory, road and heart rate give different zones<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A study on juniors found FTP measured outdoors on a climb, at 6.7%, 14-15% higher than laboratory estimates: the boundaries hold for the conditions in which they were measured.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Heart-rate zones do not coincide with power zones either, and they are not meant to. FTP rises and falls with form, threshold heart rate stays almost still: in mid-season heart-rate zone 2 can correspond to power zone 3.<\/p>\n\n\n\n<p class=\"nota-automatica wp-block-paragraph\">Article written with the help of <a href=\"https:\/\/mimir.bot\/\">Mnemosyne<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Sources<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Allen H., Coggan A.R., McGregor S., \u201cTraining and Racing with a Power Meter\u201d, 3rd ed., VeloPress, 2019.<\/li><li>Engelke P., Vivan L., Dos Anjos Souza V.R., de Lira C.A.B., Weiss K., Rosemann T., Knechtle B., Andrade M.S., <a href=\"https:\/\/doi.org\/10.1016\/j.clinsp.2026.100977\">\u201cEquivalence between FTP and RCP: Assessment of association, agreement and sex effect\u201d<\/a>, Clinics (Sao Paulo), 2026, PMID 42060964, doi:10.1016\/j.clinsp.2026.100977.<\/li><li>Friel J., \u201cThe Cyclist&#8217;s Training Bible\u201d, 5th ed., VeloPress, 2018.<\/li><li>Vinetti G., Rossi H., Bruseghini P., Corti M. et al., <a href=\"https:\/\/doi.org\/10.1519\/JSC.0000000000004471\">\u201cFunctional Threshold Power Field Test Exceeds Laboratory Performance in Junior Road Cyclists\u201d<\/a>, Journal of Strength and Conditioning Research, 2023, doi:10.1519\/JSC.0000000000004471.<\/li><li>S\u00e1nchez-Jim\u00e9nez J.L., Javaloyes A., Barranco D., Pe\u00f1a-Gonz\u00e1lez I., Moya-Ram\u00f3n M., Mateo-March M., <a href=\"https:\/\/doi.org\/10.1002\/ejsc.70170\">\u201cRole-Specific Performance Profiles of Professional Cyclists in a Grand Tour\u201d<\/a>, European Journal of Sport Science, 2026, doi:10.1002\/ejsc.70170.<\/li><li><a href=\"\/en\/races\/il-lombardia-2026\/\">\u201cIl Lombardia 2026\u201d<\/a>, the race page: climb times and our watts per kilo.<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>How Coggan&#8217;s seven power zones are built from FTP, how long riders can hold each, and where pros sit on the Il Lombardia 2026 climbs, limits included.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_fagianata_traduzione":6022,"fagianata_corsa":"","notizia_livello":"","notizia_paese":"","notizia_numero":"","notizia_numero_detto":"","fagianata_via":"","disciplina":"","fagianata_anno":0,"fagianata_firma":"","_fagianata_titolo_seo":"Cycling Power Zones Explained: Z1 to Z7","_fagianata_indice":"","fagianata_tappa":0,"fagianata_tappa_data":"","footnotes":""},"categories":[289],"tags":[],"protagonisti":[],"class_list":["post-5675","post","type-post","status-publish","format-standard","hentry","category-guides","formato-guida","scheda-pezzo--tinta","tinta--strada"],"fagianata_protagonisti":[],"_links":{"self":[{"href":"https:\/\/lafagianata.it\/en\/wp-json\/wp\/v2\/posts\/5675","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lafagianata.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lafagianata.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lafagianata.it\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lafagianata.it\/en\/wp-json\/wp\/v2\/comments?post=5675"}],"version-history":[{"count":3,"href":"https:\/\/lafagianata.it\/en\/wp-json\/wp\/v2\/posts\/5675\/revisions"}],"predecessor-version":[{"id":5912,"href":"https:\/\/lafagianata.it\/en\/wp-json\/wp\/v2\/posts\/5675\/revisions\/5912"}],"wp:attachment":[{"href":"https:\/\/lafagianata.it\/en\/wp-json\/wp\/v2\/media?parent=5675"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lafagianata.it\/en\/wp-json\/wp\/v2\/categories?post=5675"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lafagianata.it\/en\/wp-json\/wp\/v2\/tags?post=5675"},{"taxonomy":"protagonisti","embeddable":true,"href":"https:\/\/lafagianata.it\/en\/wp-json\/wp\/v2\/protagonisti?post=5675"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}